YOKOGAWA SCP401-11

1. Safety-Critical Reliability

Dual-redundant architecture ensures continuous operation

Automatic failover (<50ms switchover time)

Built-in self-tests for continuous diagnostics

2. High-Performance Communication

1Gbps Ethernet backbone for safety system data

Deterministic communication for time-critical safety functions

Secure data transmission with CRC checking

3. Maintenance Advantages

Hot-swappable modules minimize downtime

LED status indicators for quick diagnostics

Predictive failure alerts via system software

In Stock
Manufacturer:
Part number: YOKOGAWA SCP401-11
Our extensive catalogue, including : YOKOGAWA SCP401-11 , is available now for dispatch to the worldwide. Brand:

Description

YOKOGAWA SCP401-11 Product Overview

The YOKOGAWA SCP401-11 is a high-performance safety communication processor designed for Yokogawa’s ProSafe-RS safety instrumented systems (SIS). This critical component provides secure, redundant communication between safety controllers and operator workstations in mission-critical process safety applications.

Key Features

✔ Dual-redundant communication paths for fault tolerance
✔ SIL 3 certified per IEC 61508
✔ High-speed safety bus communication
✔ Advanced diagnostics for system integrity monitoring
✔ Hot-swappable design for maintenance without shutdown

Technical Specifications

Parameter Specification
Model SCP401-11
Manufacturer YOKOGAWA
Type Safety Communication Processor
Safety Certification SIL 3 (IEC 61508)
Redundancy 1:1 Redundant configuration
Communication Speed 1Gbps Ethernet
Protocols Vnet/IP, ProSafe-RS Safety Bus
MTBF >150,000 hours
Power Supply 24V DC (dual redundant inputs)
Operating Temperature 0°C to +55°C
Dimensions 200mm (W) × 133mm (H) × 85mm (D)
YOKOGAWA SCP401-11

YOKOGAWA SCP401-11

Main Features & Benefits

1. Safety-Critical Reliability

Dual-redundant architecture ensures continuous operation

Automatic failover (<50ms switchover time)

Built-in self-tests for continuous diagnostics

2. High-Performance Communication

1Gbps Ethernet backbone for safety system data

Deterministic communication for time-critical safety functions

Secure data transmission with CRC checking

3. Maintenance Advantages

Hot-swappable modules minimize downtime

LED status indicators for quick diagnostics

Predictive failure alerts via system software

Application Field

Process Safety Systems

Emergency Shutdown Systems (ESD)

Fire & Gas Protection Systems

Burner Management Systems

Turbine Overspeed Protection

Critical Industries

Oil & Gas (Offshore/Onshore)

Petrochemical Plants

Nuclear Power Facilities

Pharmaceutical Manufacturing

YOKOGAWA SCP401-11

YOKOGAWA SCP401-11

Related Products

Model Description
SCP401-10 Non-redundant version
FSC401 Safety Controller
HIS4000-S Safety Operator Station
YPS100-S Safety Power Supply

Installation & Maintenance

Installation Requirements

Certified safety engineers required for installation

Proper grounding per Yokogawa specifications

Redundant power supplies mandatory

Maintenance Procedures

Annual diagnostic tests

Quarterly connection checks

Firmware updates per safety bulletins