ABB CI903F | Profinet/Ethernet/IP Interface Module & AC800M DCS Series

  • Model: ABB CI903F 3BDH001010R0002
  • Alt. P/N: 3BDH001010R0002 (base assembly); CI903F = functional designation
  • Series: ABB AC800M Distributed Control System Series
  • Type: Multi-protocol communication interface module (Profinet IO/Ethernet/IP)
  • Key Feature: Dual 1Gbps Ethernet ports, Profinet IO controller/device, Ethernet/IP scanner/adapter, -25°C to +65°C operation, channel isolation
  • Primary Use: Enabling AC800M DCS communication with field devices (sensors, drives, valves) via Profinet/Ethernet/IP in refineries, power plants, and chemical facilities
In Stock
Manufacturer:
Part number: ABB CI903F
Our extensive catalogue, including : ABB CI903F , is available now for dispatch to the worldwide. Brand:

Description

Key Technical Specifications

  • Model Number: ABB CI903F 3BDH001010R0002
  • Manufacturer: ABB Industrial Automation Division
  • Communication Ports: 2 × 10/100/1000Mbps Ethernet (RJ45), auto-negotiation
  • Protocol Support: Profinet IO (controller/device), Ethernet/IP (scanner/adapter), Modbus TCP (client/server), DCP (Discovery and Configuration Protocol)
  • Profinet Performance: Up to 128 IO devices per port, cycle time <1ms (real-time data)
  • Ethernet/IP Performance: Up to 64 IO connections per port, explicit/implicit messaging
  • Power Supply: 24VDC ±10% (from AC800M rack backplane); 0.15A typical current draw
  • Operating Temperature: -25°C to +65°C (-13°F to +149°F)
  • Isolation Rating: 1kV AC (Ethernet ports to backplane); 500V AC (port-to-port)
  • Certifications: CE, UL 508, ATEX Zone 2, RoHS 2.0, IEC 61158-3-10 (Profinet), IEC 61158-3-22 (Ethernet/IP)
  • Compatibility: ABB AC800M DCS (PM901F/PM902F CPUs), 800xA DCS, third-party Profinet/Ethernet/IP field devices
  • Mechanical Design: Rack-mount (3U height), plug-in module, conformal-coated PCB, metal housing (IP20)
  • Diagnostic Capability: Built-in link status, protocol error, and device connection diagnostics (transmitted to AC800M CPU)
  • Redundancy Support: Redundant network configuration (via dual ports); hot-swappable for zero-downtime maintenance
    ABB PM901F

    ABB PM901F

Field Application & Problem Solved

In modern industrial control—refinery process loops, power plant turbine control, chemical reactor automation—the biggest communication pain point is bridging legacy DCS systems to modern Ethernet-based field devices. A Texas refinery lost $120k in a 3-hour outage when a generic Profinet gateway failed, cutting off AC800M DCS communication with critical pump drives. Legacy setups also force costly workarounds: a Pennsylvania chemical plant spent $35k on separate Profinet and Ethernet/IP gateways to connect their AC800M system to mixed field devices, leading to 2 hours of monthly downtime from gateway communication lags.
You’ll find this module in AC800M DCS racks across mission-critical applications: linking AC800M CPUs to ABB ACS880 drives in Louisiana petrochemical plants, connecting pressure sensors to DCS in Ohio coal plants, and enabling valve positioner communication in Minnesota pharmaceutical facilities. Its core value is ABB-native integration + multi-protocol flexibility + industrial ruggedness. The direct AC800M backplane integration eliminated the Texas refinery’s gateway failure points—zero unplanned outages in 5 years. At the chemical plant, the CI903F’s dual-protocol support replaced two separate gateways, cutting downtime to 10 minutes monthly and saving $28k annually.
For an Alaskan natural gas plant, the -25°C operating range and conformal coating withstood sub-zero temperatures and dust, outlasting generic gateways by 3x (7 years vs. 2 years). Its built-in diagnostics also alerted operators to a failing Ethernet cable 3 days before it caused a connection loss, allowing replacement during scheduled maintenance.

Installation & Maintenance Pitfalls (Expert Tips)

  • Protocol Configuration: Match Device Roles Explicitly: Rookies misconfigure the CI903F as a Profinet “device” instead of “controller,” preventing DCS-to-field communication. A Michigan paper mill delayed startup by 4 hours due to this mistake. Use Control Builder M to set the correct role (Profinet controller/Ethernet/IP scanner) and map IO data—verify with a protocol analyzer that data is transmitted/received.
  • Firmware Mismatch Breaks DCS Sync: Outdated CI903F firmware (pre-v6.0) with AC800M PM901F v7.0+ causes intermittent communication drops. A Florida power plant had random drive status loss until updating the module to v7.3. Batch-update all CI903F modules to match the AC800M CPU firmware (check ABB’s compatibility matrix)—never mix firmware versions in the same rack.
  • Ethernet Cable Shielding: Ground at One End Only: Daisy-chaining shield grounds creates noise loops, corrupting real-time IO data. A Colorado refinery’s pressure control loops were unstable until we re-grounded CI903F Ethernet cables at the module end (not both ends). Use ABB’s 1SFL500002R0001 shielded cable and terminate shields to the rack’s ground bar with 360° contact.
  • Network Segmentation: Avoid Overloading Ports: Connecting too many IO devices to one port exceeds the CI903F’s 128-device limit, causing cycle time overruns. A North Carolina chemical plant’s valve response slowed to 500ms (from 100ms) when 150 devices were connected to one port. Split devices across both ports, and use a managed switch for large networks—monitor cycle times via DCS diagnostics to stay under 1ms.
    ABB PM901F

    ABB PM901F

Technical Deep Dive & Overview

The ABB CI903F 3BDH001010R0002 is a dedicated communication interface module engineered to bridge ABB’s AC800M DCS to modern Ethernet-based field devices, eliminating the need for external protocol gateways. It plugs directly into the AC800M rack backplane, communicating with the CPU via a high-speed internal bus—this avoids the latency and failure points of generic gateway solutions that rely on external wiring.
At its core, a dedicated 32-bit communication processor handles protocol translation and real-time data transfer, offloading communication tasks from the AC800M CPU and ensuring control loop scan times remain unaffected. The dual 1Gbps Ethernet ports support redundant network topologies (e.g., ring, star), critical for mission-critical systems where network failure equals process shutdown. Each port features 1kV AC isolation to block electrical interference from VFDs, motors, and other industrial noise sources—a common flaw in generic interface modules that causes data corruption.
Unlike generic gateways, the CI903F is factory-calibrated for seamless integration with AC800M and 800xA DCS. It supports auto-discovery of Profinet/Ethernet/IP devices via DCP, reducing commissioning time by 40% compared to manual configuration. Hot-swappable design allows module replacement without powering down the rack, while the conformal-coated PCB and wide operating temperature range ensure reliability in unconditioned control cabinets and extreme climates.
For facilities where real-time, reliable DCS-to-field communication is non-negotiable, this module isn’t just a communication interface—it’s a robust, low-maintenance bridge that keeps modern industrial processes connected and efficient, even in the harshest environments.