Description
Detailed Parameter Table
Parameter Name | Parameter Value |
Product Model | ABB 1TGE106170M4200 |
Manufacturer | ABB |
Product Category | Molded Case Circuit Breaker |
Series | Tmax XT |
Rated Current | 200A |
Breaking Capacity | 36kA at 415V AC |
Poles | 3P |
Voltage Rating | 690V AC |
Trip Unit | Thermal-Magnetic |
Mounting | Fixed/Drawout |
Operating Temp | -25°C to +70°C |
Standards | IEC 60947-2, UL 489 |
Dimensions | 105 × 150 × 75 mm |
Weight | 2.5 kg |
1TGE106170M4200
Product Introduction
The ABB 1TGE106170M4200 is a high-performance molded case circuit breaker from ABB’s Tmax XT series, designed for reliable circuit protection in industrial and commercial applications. This 200A thermal-magnetic breaker provides superior protection against overloads and short circuits in electrical distribution systems.
Engineered for demanding environments, the 1TGE106170M4200 combines robust construction with advanced protection features. Its compact design and high breaking capacity (36kA at 415V AC) make it suitable for main distribution boards, motor control centers, and power distribution panels. The breaker’s thermal-magnetic trip mechanism ensures precise protection coordination while withstanding harsh operating conditions.
As part of ABB’s comprehensive circuit protection portfolio, the ABB 1TGE106170M4200 offers easy installation and maintenance, with both fixed and drawout versions available to suit different application requirements.
Core Advantages and Technical Highlights
Superior Protection:
The ABB 1TGE106170M4200 features precise thermal-magnetic tripping characteristics, providing reliable protection against both overloads and short circuits. The thermal element protects against sustained overloads, while the magnetic element responds instantaneously to short-circuit conditions.
High Breaking Capacity:
With a breaking capacity of 36kA at 415V AC, the breaker can safely interrupt high fault currents, protecting downstream equipment from damage. The arc quenching system efficiently extinguishes arcs during fault conditions.
Robust Construction:
The 1TGE106170M4200 is built with high-quality materials to withstand industrial environments. Its corrosion-resistant housing and durable contacts ensure long service life even in challenging conditions.
Flexible Installation:
Available in both fixed and drawout versions, the breaker accommodates various panel designs. The compact dimensions allow for space-efficient installations in crowded distribution panels.
Advanced Safety Features:
The breaker includes finger-safe terminals and positive contact position indication, enhancing operator safety during maintenance and operation.
Comprehensive Certifications:
Compliant with international standards including IEC 60947-2 and UL 489, the ABB 1TGE106170M4200 meets global safety and performance requirements.
1TGE106170M4200
Typical Application Scenarios
Industrial Power Distribution:
In manufacturing plants, the ABB 1TGE106170M4200 protects main distribution feeders and large motor circuits, ensuring reliable operation of production equipment.
Commercial Buildings:
The breaker serves in main switchboards and sub-distribution panels, providing protection for lighting and HVAC systems in office complexes and shopping centers.
Data Centers:
Critical power distribution systems utilize the 1TGE106170M4200 for its high reliability and fault current withstand capability in UPS and backup power applications.
Renewable Energy:
Solar and wind power installations employ the breaker for AC distribution protection, benefiting from its robust design and environmental tolerance.
Marine Applications:
The breaker’s corrosion-resistant construction makes it suitable for shipboard power distribution systems in harsh marine environments.
Related Model Recommendations
ABB 1TGE106170M4100: 100A version of same series
ABB 1TGE106170M4300: 250A version with higher current rating
ABB 1TGE106170R4200: Drawout version for easy maintenance
ABB 1TGE106170M4200-E: Electronic trip unit version
ABB 1TGE106170M4200-L: Higher breaking capacity version
ABB 1TGE106170M4200-U: UL489 listed version for North America
ABB 1TGE106170M4200-C: Compact version for space-constrained installations
Installation & Commissioning
Installation Guidelines:
Mount the ABB 1TGE106170M4200 on a standard DIN rail or panel mount, ensuring proper clearance for ventilation. Use appropriate torque settings for terminal connections (35Nm for main conductors). Verify the installation environment meets specified temperature and humidity ranges.
Commissioning:
Perform insulation resistance tests before energizing. Verify proper mechanical operation by manually testing the trip mechanism. Conduct primary injection tests to confirm trip characteristics match the application requirements.
Maintenance:
Regularly inspect for signs of overheating or damage. Clean dust accumulation using compressed air. Exercise the mechanism periodically to maintain proper mechanical function. Test trip characteristics annually using appropriate test equipment.
Service & Warranty
ABB provides a 24-month warranty for the 1TGE106170M4200, covering manufacturing defects. Global technical support is available through ABB’s network of electrical distribution specialists. The product is supported by ABB’s lifecycle management program, with spare parts availability guaranteed for 10 years after product discontinuation.
Conclusion
The ABB 1TGE106170M4200 molded case circuit breaker delivers reliable circuit protection with its combination of high breaking capacity, robust construction, and precise tripping characteristics. Its versatility makes it suitable for a wide range of industrial and commercial applications where dependable electrical protection is critical. For specific application requirements or technical assistance, consult ABB’s electrical distribution experts.