Woodward 37331-02 | 3-Gauge Kit 3-3/8 in Speedo & Dual Quads

  • Model:​ Woodward 37331-02
  • Brand:​ New Vintage USA (NVU)
  • Series:​ Woodward Series
  • Core Function:​ Integrates a 3-3/8″ speedometer and two 3-3/8″ quad gauges for consolidated dashboard monitoring.
  • Product Type:​ Analog Gauge Kit (3-Gauge Set)
  • Key Specs:​ 3-3/8 in (85 mm) diameter | 0-140 mph / 0-8000 RPM | NVU Direct Drive
In Stock
Manufacturer:
Part number: Woodward 37331-02
Our extensive catalogue, including : Woodward 37331-02 , is available now for dispatch to the worldwide. Brand:
The listed price is not final; the actual selling price is negotiable based on current market conditions.

Description

Product Introduction

The Woodward 37331-02 is a 3-gauge dashboard kit packing a 3-3/8″ speedometer and two 3-3/8″ quad gauges. It runs on NVU’s Phoenix Direct Drive, needing just one 12 Vdc tap on the speedo to power the daisy-chained secondary units.

This beige-face Woodward 37331-02 offers period-correct styling, contrasting with the black-face 37331-01. The OLED trip window refreshes at 10 Hz. Post-calibration sweep settling typically lands under 1.2 seconds from a cold start.

Woodward 47371-01

Woodward 47371-01

Key Technical Specifications

Parameter Value
Kit Composition 1x Speedometer, 2x Quad Gauges (Oil/Fuel/Water/Volts)
Gauge Diameter 3-3/8 in (85 mm)
Outer Diameter 3-11/16 in (94 mm)
Speed Range 0-140 mph (0-240 kph programmable)
Tach Range (Quad) 0-8000 RPM (discrete input per gauge)
Oil Pressure Range 0-100 psi
Fuel Level Programmable (0-90Ω / 240-33Ω)
Water Temp Range 100-250 °F (verify with OEM datasheet)
Face Color Beige
Graphics Black / Wraparound Deco
Pointer Color Red
Bezel Polished stainless steel
Lens Domed glass
Wiring NVU Direct Drive (Daisy-chain ports)

 

Quality Control Process (Engineer’s Perspective)

  1. Incoming Verification:​ Cross-check the NVU Woodward 37331-02 serials on all three 85 mm housings against the bill of lading. Inspect domed glass for optical distortion or trapped lint under the bezel lip.
  2. Live Functional Test:​ Energize the speedo at 12 Vdc. Feed 60 Hz to the tach leads on both quads. All needles sweep full scale; check OLED segments for dead pixels during the self-test routine.
  3. Electrical Parameter Test:​ Sweep a pot across the fuel sender pins on the secondary quad using a Fluke 115. Confirm ADC tracking stays within 2% of the primary gauge—daisy-chain sync errors surface here.
  4. Firmware Verification:​ Trigger the one-mile calibration via the remote button. Photograph the OLED confirming the PPM count locked—well, technically it supports push-button config, but only on firmware v3.2+.
  5. Final QC & Packaging:​ Slot each gauge into die-cut anti-static foam inserts. Coil the Direct Drive jumpers loosely. Apply a “QC Passed – 24hr Burn-in” label with the date before sealing the master carton.

 

Replacement Pitfall Guide

Daisy-Chain Topology:​ The Woodward 37331-02 enforces a strict signal flow. Speedo Out feeds Quad 1 In, Quad 1 Out feeds Quad 2 In. Swapping the quad order breaks the data link.

Hole Pattern Spacing:​ Three 3-3/8″ cutouts demand precise 120 mm center-to-center spacing. Off by 2 mm and the bezels clash—mock up the panel with a drill template first.

Shared Sensor Grounds:​ Both quads tie to a common sensor ground on the speedo. Ground loops from mixed-case senders (e.g., an oil sender body touching the block) cause crosstalk on fuel readings.

Power Headroom:​ Running two quads plus the speedo draws ~150 mA at 12 Vdc. Ensure your fused supply has 20% headroom; voltage sag below 11.5 Vdc triggers needle chatter at idle.

ESD to OLED:​ The display drivers across all three units are static-sensitive. Discharge to chassis ground before handling connectors in dry shop air—though your mileage may vary on humidity control.

Keep these in mind and you’ll cut 90% of rework time.

Woodward 47371-01

Woodward 47371-01

Compatibility Matrix & Benchmarks

  • Woodward 37331-02 → Woodward 37331-01 : Direct — Face color swap (Beige vs Black)
  • Woodward 37331-02 → Woodward 37204-02 : Needs Adaptation — 37204 is a 2-gauge kit with identical tech
  • Woodward 37331-02 → AutoMeter 4797 : Incompatible — Harness architecture and sender logic differ
  • Sweep Response:​ < 1.2 seconds (0-140 mph step change)
  • Signal Input Range:​ 2,000 to 40,000 PPM (Speedo), 0.5-333 Hz (Tach)
  • Daisy-Chain Load:​ < 100 mA total draw on the slave ports