ICS Triplex T8831 | SIL 3 Certified Analog Signal Acquisition Module for Hazardous Areas

  • Model: T8831
  • Series: ICS Triplex Trusted Series
  • Type: Analog Input Field Termination Assembly (FTA)
  • Key Feature: Equipped with 40 analog input channels, supporting 4 – 20mA standard signals (input range 0 – 24mA); each channel is configured with a fused field power supply and has on-board LED indicators to monitor the integrity of the field power supply; supports DIN rail installation and 24VDC operation.
  • Primary Use: It serves as an interface between non-flameproof field devices in hazardous areas and the T8431 module. It is widely used in oil and gas, chemical industry, power and other industries to realize the acquisition and transmission of analog signals from sensors and other equipment, ensuring the stable operation of critical industrial control systems.
In Stock
Manufacturer:
Part number: ICS Triplex T8831
Our extensive catalogue, including : ICS Triplex T8831 , is available now for dispatch to the worldwide. Brand:

Description

Key Technical Specifications

Parameter Details
Manufacturer ICS Triplex (affiliated to Rockwell Automation)
Voltage & Current Works with 24VDC power supply; the supply voltage range can also reach 20 – 32VDC; supports 4 – 20mA nominal input signals
Accuracy & Resolution The measurement accuracy is ±0.2% full scale deflection, and the proof test accuracy is ±0.5% full scale deflection; the resolution is 12 – bit with 4096 counts
Physical Indicators There are differences in size data from different merchants. One set of data is 30.3cm×9.3cm×26.6cm with a weight of 2.94kg, and another set is 30cm×20cm×20cm with a weight of 2kg; it supports standard DIN rail installation
Environmental Adaptability The operating temperature is 0°C – 60°C, and the non-operating temperature is -25°C – 70°C; it can work in an environment with 5% – 95% non-condensing humidity; it can work normally at an altitude of up to 2000m without derating
Safety Certification Complies with IEC 61508 SIL 3 standard, which can meet the safety and reliability requirements of safety-critical industrial applications
ICS TRIPLEX T8311

ICS TRIPLEX T8311

Field Application & Problem Solved

In oil refineries, chemical reaction workshops and other scenarios, a large number of sensors are used to monitor parameters such as pressure and temperature. The analog signals generated by these sensors in hazardous areas need to be safely and accurately transmitted to the core control module. If the signal transmission is distorted or interrupted, it will lead to wrong control instructions and even major safety accidents.

The T8831 can effectively solve these problems. For example, in an offshore oil drilling platform, the module is connected to multiple pressure sensors in the oil transmission pipeline area. Its 40 channels can simultaneously collect the pressure analog signals of multiple pipelines. The fused power supply design of each channel can avoid the overall signal interruption caused by a single channel failure. When the power supply of a certain channel is abnormal, the LED indicator will promptly remind the staff, and the signal can still be stably transmitted to the T8431 module through other normal channels. In a large chemical plant, its SIL 3 safety certification ensures that the analog signals of equipment such as reaction kettles are not distorted during transmission, preventing production accidents caused by inaccurate data monitoring and ensuring the safety and stability of the production process.

Installation & Maintenance Pitfalls (Expert Tips)

  1. Ignoring Matching with Specific Modules: The module is specially designed for the T8431 TMR analog input module. Random matching with other analog input modules will lead to problems such as incompatible interfaces and unsmooth signal transmission. Before installation, it is necessary to confirm that the connected core module is the T8431 model.
  2. Neglecting Channel Fuse Inspection: Each channel of the module is equipped with a fused field power supply. If the fuse status is not checked before installation, the channel may fail to work normally after installation. It is necessary to inspect the fuse one by one before installation and replace the damaged fuse in time.
  3. Improper Wiring of Two-Wire Field Devices: It adopts the industry-standard two-wire field device connection mode. If the positive and negative poles are connected incorrectly or the wiring is loose during installation, it will cause signal loss or poor contact. It should be wired strictly according to the manual and the firmness of the wiring should be checked after installation.
  4. Disregarding Environmental Altitude Limits: The module can work normally without derating only when the altitude is within 2000m. If it is installed in high-altitude areas such as plateaus beyond this range without taking derating measures, its working stability will be affected. It is necessary to evaluate the installation location in advance and take corresponding protective measures if necessary.
    ICS TRIPLEX T8311

    ICS TRIPLEX T8311

Technical Deep Dive & Overview

The core advantage of the T8831 lies in its balance of multi-channel signal acquisition and high safety performance. The design of 40 input channels can meet the signal acquisition needs of a large number of field sensors at one time, avoiding the complexity of using multiple modules for splicing and reducing the difficulty of system integration. The independent fused power supply for each channel realizes the independent protection of the channels. When a single channel has an overcurrent fault, only the corresponding fuse is damaged, and other channels can work normally, which conforms to the high fault tolerance requirements of industrial safety systems.

In terms of safety, its SIL 3 certification enables it to be used with confidence in hazardous areas and critical process links, solving the problem of potential safety hazards in signal transmission in harsh environments. In terms of operation and maintenance, the on-board LED indicators allow the staff to intuitively grasp the power supply status of each channel without disassembling the equipment, which improves the efficiency of fault location. In addition, its compatibility with T8100 processor chassis and T8300 expander chassis also enables it to be flexibly integrated into different Trusted series system architectures, enhancing its adaptability in various industrial scenarios. Moreover, its derivative model T8831C has the same core functions, providing convenient options for enterprises’ later equipment replacement and system expansion.