ICS Triplex T3481 | Redundant Industrial Output Module for Emergency Shutdown

  • Model: T3481
  • Series: ICS Triplex product family
  • Type: Monitored guarded output module
  • Key Feature: It has 16 monitored output channels; adopts dual – redundant fail – safe architecture and triple – redundant protection level; is equipped with automatic diagnostic function and front – panel indicators; supports hot replacement and is compatible with relevant communication protocols.
  • Primary Use: It is mainly used to control field devices such as solenoid valves, relays and actuators in industrial scenes. It is applied to safety instrumented systems, emergency shutdown systems and fire and gas systems to ensure the safe and stable operation of critical industrial processes.
In Stock
Manufacturer:
Part number: ICS Triplex T3481
Our extensive catalogue, including : ICS Triplex T3481 , is available now for dispatch to the worldwide. Brand:

Description

Key Technical Specifications

Parameter Details
Manufacturer ICS Triplex (affiliated to Rockwell Automation)
Electrical Parameters The operating voltage range covers 24 – 48 VDC; the output current can reach up to 2A per channel, and the current rating can reach 5A when the voltage is 24VDC. There is 2500 minimum electrical isolation between the field and logic circuits, and the surge protection level can reach 6kV contact discharge.
Physical Indicators There are differences in size data from different merchants. One set of data is 100mm×120mm×80mm with a weight of about 0.95kg, and another set is 27cm×26cm×40cm with a weight of 4.12kg. The derivative model T3481A is 17.4cm×10.5cm×3.5cm and weighs 0.7kg.
Environmental Adaptability The operating temperature ranges from -20°C to +60°C, and the storage temperature ranges from -40°C to +85°C. It can work in an environment with 5% – 95% non – condensing humidity and can resist high mechanical vibration.
Safety & Compliance It has SIL 3 certification and Risk Class 5 certification. It complies with EMI standards IEC 801 and ANSI/IEEE C37.90, and also meets the safety requirements of DIN V VDE 0801, UL 508 and other standards.
ICS Triplex T8431C

ICS Triplex T8431C

Field Application & Problem Solved

In industries such as petrochemical and power generation, once the control signal of field executive components such as solenoid valves and relays is wrong or interrupted, it may lead to dangerous situations such as equipment misoperation and leakage of harmful media, and even trigger major safety accidents.

The T3481 can effectively avoid such risks. For example, in an offshore oil platform’s emergency shutdown system, the module is responsible for sending control signals to the solenoid valves of multiple oil transmission pipelines. Its dual – redundant architecture ensures that even if one set of circuits fails, the other set can take over the work immediately, avoiding signal interruption. When a short – circuit fault occurs in the wiring of a certain relay connected to the module, the automatic diagnostic function can quickly detect the fault and send an alarm through the front – panel indicator. The staff can promptly handle the fault without affecting the operation of other channels. In a large chemical plant’s fire and gas system, its SIL 3 certification ensures that the module can reliably send out action signals to fire – fighting equipment such as fire water pumps when a fire is detected, preventing the fire from spreading due to equipment failure to start in time.

Installation & Maintenance Pitfalls (Expert Tips)

  1. Neglecting Anti – Static Measures: The module’s internal circuits are sensitive to static electricity. If maintenance personnel do not use anti – static work areas and grounding straps when installing or replacing the module, electrostatic damage to the circuits may occur. It is necessary to strictly abide by anti – static operation specifications during operation.
  2. Ignoring Indicator Check: The front – panel indicators can reflect the module’s fault, output and other statuses. If the indicator status is not confirmed after installation, potential problems such as poor output contact cannot be found in time. It is necessary to carefully check whether each indicator is in a normal state after installation.
  3. Incorrect Fuse Replacement: The module is equipped with fuses, and the fuses are accessible from the front panel. If non – standard fuses are used during replacement, the circuit cannot be effectively protected, or the fuses blow frequently. It is necessary to select fuses that meet the specifications of the module.
  4. Rough Hot – Swap Operation: Although the module supports hot replacement, rough plugging and unplugging during the replacement process may damage the module interface and the connected chassis socket. It should be operated gently in accordance with the manual steps to avoid unnecessary damage.
    ICS Triplex T8431C

    ICS Triplex T8431C

Technical Deep Dive & Overview

The core advantage of the T3481 lies in its excellent fail – safe performance and comprehensive fault handling capabilities. Its dual – redundant fail – safe architecture and triple – redundant protection level fundamentally reduce the impact of single – point faults, which is in line with the high – reliability requirements of safety – critical systems. The automatic diagnostic function that can detect open circuits, short circuits and fuse blowouts enables hidden dangers to be found in time, avoiding serious consequences caused by fault accumulation.

In terms of usability, the design of front – panel indicators and accessible fuses allows staff to quickly locate and handle faults, improving maintenance efficiency. Its hot – swap feature also avoids production losses caused by system shutdown due to module maintenance. In the market, the module is usually supplied in original packaging, and most suppliers provide a 12 – month warranty service. In addition, its derivative model T3481A has similar core functions such as 16 guarded outputs and fault – tolerant operation, providing more options for system expansion and equipment replacement.