GE DS3800NFCD1S1 | SCR Firing Circuit Board for Mark IV Static Exciter Bridge

  • Model: DS3800NFCD1S1
  • Alt. P/N: NFCD1S (functional tag)
  • Series: Mark IV Speedtronic DS3800
  • Type: SCR firing circuit board
  • Key Feature: 6 isolated gate pulses, 0-10 V angle command, 1500 Vrms isolation
  • Primary Use: Converts low-level angle reference into high-energy gate pulses for static exciter SCR bridge
In Stock
Manufacturer:
Part number: DS3800NFCD1S1
Our extensive catalogue, including : DS3800NFCD1S1 , is available now for dispatch to the worldwide. Brand:

Description

Key Technical Specifications
  • Model Number: DS3800NFCD1S1
  • Manufacturer: General Electric
  • Logic Voltage: +5 V @ 1.2 A, ±12 V @ 200 mA from rack back-plane
  • Gate Outputs: 6 × 30 V pulses, 2 A peak, 200 µs width, transformer-isolated
  • Input Command: 0-10 V differential from NAIF/NVRC firing-reference card
  • Isolation: 1500 Vrms gate-to-logic, 500 V phase-to-phase
  • Pulse Shape: Dual 30 V / –5 V spike to guarantee SCR turn-on at 0 °C
  • Connectors: 96-pin DIN to back-plane, six 2-position pluggable for gate leads
  • Protection: 39 V MOV on each output, 2 A PTC resettable fuse per gate
  • Operating Temperature: –20 °C to +70 °C inside turbine cabinet
  • Dimensions: 6.3 × 9.0 in (160 × 229 mm), single-slot 6U Euro-card

    DS3800HHTB1D1D

    DS3800HHTB1D1D

Field Application & Problem Solved
A 1987 frame-5 static exciter doesn’t fire SCRs with fairy dust—it needs a rock-solid 30 V pulse delivered to six gate terminals at the exact micro-second the angle command says “go.” The DS3800NFCD1S1 is the card that makes that happen. It sits in the exciter rack, listens to a 0-10 V angle reference from the NAIF card, and spits out six 30 V pulses 60° apart to turn on the big SCRs in the bridge. When the card drifts—usually a gate transformer primary opens—you see field current collapse and the generator voltage sag 5 %; swap the board, re-torque the gate leads, and the bridge comes back to life. You’ll find this PCB in any plant that still runs a three-phase SCR exciter: paper-mill back-pressure sets, refineries, and every frame-5/6 peaker that never upgraded to digital AVRs. Its core value is brute force: the gate pulse is 2 A peak, enough to fire 1000 A SCRs, yet the card is isolated so a shorted SCR never blows up the Mark IV logic.
Installation & Maintenance Pitfalls (Expert Tips)
Gate leads reversed—bridge shorts on power-up
The six gate plugs are keyed alike but pin-outs alternate phase-to-phase. Land G1 on G2 and you fire the wrong SCR pair—bridge crowbars, fuse blows, unit trips. Always ring-out gate leads with a DMM before you energize; you should see 18 Ω primary, not a dead short.
MOV fatigue—pulse amplitude drops, field current sags
A 39 V MOV on each output clamps inductive kick. After 15 years the MOV drifts low; pulse tops out at 24 V instead of 30 V and SCRs misfire cold. If field current sags 3 % in winter, swap the MOVs or the whole card—gate drive is not field-repairable.
Missing nylon washer—card arcs to rack
The four corner holes are through-plated. Forget the fiber washers and the card edge sits 0.5 mm proud; 125 V field voltage finds the rack paint, arcs, and blows a hole in the ground plane. Use the original GE shoulder washers or add 2 mm nylon spacers—torque to 8 in-lb, no more.
Angle command open—bridge runs away to 90°
The 0-10 V input is differential; lose the negative lead and the card sees 0 V, thinks “full field,” and hammers 90° into the SCRs. Generator volts shoot to 120 %. Always check continuity on the NAIF cable before you close the breaker—30 s with a meter saves a manual trip.

DS3800HHTB1D1D

DS3800HHTB1D1D

Technical Deep Dive & Overview
DS3800NFCD1S1 is a six-channel gate pulse amplifier frozen in 1987 silicon. A 741 op-amp buffers the 0-10 V angle command; a 555 one-shot generates a 200 µs pulse; six gate-drive transformers step the pulse up to 30 V at 2 A peak. Each output has a 39 V MOV to clip inductive spikes and a 2 A PTC fuse that resets when the short clears. Because the transformers are 1:1:1, you can swap the card hot and the exciter never knows—just make sure you kill the 125 VDC field breaker first or you’ll arc-weld the gate leads. Think of it as a ruggedized ignition module for SCRs; treat the gate plugs like spark-plug wires and the bridge will keep the generator floating at exactly 13.8 kV for another thirty years

.