Emerson VE4006P2 Industrial Redundant Serial Port Card

  • Model: VE4006P2
  • Brand: Emerson (DeltaV)
  • Series: DeltaV Distributed Control System
  • Core Function: Provides redundant RS-232/485 serial communication with automatic failover for critical field devices.
  • Product Type: Redundant Serial Interface Module
  • Key Specs: Dual Independent Ports, Hot-Swappable, Backplane Powered
  • Condition: New Original (New Surplus)

 

In Stock
Manufacturer:
Part number: EMERSON VE4006P2
Our extensive catalogue, including : EMERSON VE4006P2 , is available now for dispatch to the worldwide. Brand:
The listed price is not final; the actual selling price is negotiable based on current market conditions.

Description

Product Core Brief

  • Model: VE4006P2
  • Brand: Emerson (DeltaV)
  • Series: DeltaV Distributed Control System
  • Core Function: Provides redundant RS-232/485 serial communication with automatic failover for critical field devices.
  • Product Type: Redundant Serial Interface Module
  • Key Specs: Dual Independent Ports, Hot-Swappable, Backplane Powered
  • Condition: New Original (New Surplus)

 

Key Technical Specifications

Parameter Value
Module Type Redundant Serial Interface Module
Port Configuration 2 Independent Serial Ports
Supported Protocols RS-232C / RS-422A / RS-485
Max Data Rate 115.2 kbps
Redundancy Auto-Failover, Hot-Swappable
Power Source Backplane Supplied (Nominal 24 VDC)
Operating Temp 0 to 55 °C
System Compatibility DeltaV DCS Backplane
Emerson VE4006P2

Emerson VE4006P2

 

Product Introduction

Serial communication failures can silently disrupt critical field devices like modems, printers, or legacy analyzers. The Emerson is a redundant serial interface module designed to eliminate this single point of failure within the DeltaV DCS. It provides two independent serial ports with automatic failover, ensuring continuous communication even if the primary path degrades.

This module draws power directly from the DeltaV backplane, eliminating the need for separate field power supplies and simplifying cabinet wiring. Field maintenance teams consistently report that the hot-swappable design allows them to replace a faulty unit mid-shift without triggering process alarms or requiring a system shutdown.

 

Key Selling Points & Differentiators

  • True Redundant Architecture: Features automatic failover between active and standby channels; not recommended for simplex applications where redundancy is unnecessary.
  • Hot-Swappable Design: Allows replacement under power with verified ESD precautions, minimizing planned downtime during maintenance windows.
  • Backplane Powered Operation: Eliminates external field power supplies, reducing panel wiring complexity and potential ground loop issues.
  • Rigorous Live Bench Testing: Every unit undergoes a 24-hour continuous load test and full-scale I/O simulation before shipping.
  • New Surplus Availability: Factory-sealed condition with verified source traceability, bypassing typical OEM lead times for discontinued hardware.
  • Anti-Counterfeit Verification: Serial numbers are checked against manufacturer databases during incoming inspection to guarantee authenticity.
Emerson VE4006P2

Emerson VE4006P2

FAQ

Yes, but it’s overkill. The module supports simplex operation, but you’re paying for redundancy you won’t use. If your device doesn’t require failover, consider a standard serial card to reduce spare parts inventory costs.

I have a VE4006P1 on hand. Can I use it as a direct replacement?
The P1 and P2 variants typically denote firmware or hardware revisions. While they are often mechanically compatible, you must verify the firmware version matches your DeltaV system controller. Always check the DeltaV hardware manual for backward compatibility notes before swapping suffixes.

Do I need to configure redundancy in DeltaV Explorer before installing?
Yes. The controller must be configured to recognize the redundant pair and set the failover parameters. I always recommend backing up your database and running a hardware scan after insertion to ensure the controller properly identifies the active and standby channels.

What happens if I remove the active module without checking standby health?
You risk a process communication gap. Always verify the standby channel is healthy via front-panel LEDs or DeltaV diagnostics before extracting the active side. Follow approved hot-swap procedures and use ESD protection to prevent backplane damage.

Is there a warranty on this new surplus unit?
Yes. All new surplus modules come with a standard 12-month functional warranty. If the unit fails during normal operation within that period, we provide a direct replacement. We also include our internal test report with every shipment so you can verify the 24-hour load test results before installation.