ABB HC800

Advanced protection technology:

The ABB HC800 incorporates a PR122/P-LSI electronic trip unit with adjustable protection settings for overload (L), short-circuit (S), and instantaneous (I) protection. The ground fault protection (optional) provides enhanced system safety.

Robust construction:

Featuring a thermoplastic glass-fiber reinforced housing, the HC800 withstands mechanical stress and electrical arcing. The current-limiting design reduces let-through energy during faults, protecting downstream equipment.

Flexible installation:

The breaker supports both front and rear cable connections, accommodating various panel layouts. The compact design allows for high-density installations, optimizing cabinet space utilization.

User-friendly features:

The ABB HC800 includes a clear status indication (ON/OFF/TRIPPED) and trip cause indication for quick troubleshooting. The rotary handle operation provides smooth and reliable manual control.

High reliability:

With a mechanical life of 20,000 operations and wide temperature range (-25°C to +70°C), the HC800 delivers dependable performance in diverse operating conditions.

In Stock
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.

Description

Detailed Parameter Table

Parameter Name Parameter Value
Product Model ABB HC800
Manufacturer ABB
Product Category High-Current Circuit Breaker
Rated Current 800A
Breaking Capacity 65kA at 415V AC
Pole Configuration 3P/4P
Rated Voltage 690V AC
Trip Unit PR122/P-LSI
Protection Functions Overload, Short-circuit, Ground Fault
Operating Temperature -25°C to +70°C
Mechanical Life 20,000 operations
Connection Type Front or rear cable connection
Dimensions (W×H×D) 158×258×125 mm (3P)
Certifications IEC 60947-2, UL 1066
ABB HC800

ABB HC800

Product Introduction

The ABB HC800 is a high-performance molded case circuit breaker designed for critical power distribution applications requiring reliable protection up to 800A. Part of ABB’s comprehensive circuit breaker portfolio, the HC800 combines advanced protection features with robust construction for industrial and commercial electrical systems.

Engineered for demanding environments, the ABB HC800 features a current-limiting design that provides superior protection against short-circuit currents. Its compact footprint and flexible mounting options make it ideal for space-constrained installations, while the advanced trip unit ensures precise coordination with downstream protective devices.

Core Advantages and Technical Highlights

Advanced protection technology:

The ABB HC800 incorporates a PR122/P-LSI electronic trip unit with adjustable protection settings for overload (L), short-circuit (S), and instantaneous (I) protection. The ground fault protection (optional) provides enhanced system safety.

Robust construction:

Featuring a thermoplastic glass-fiber reinforced housing, the HC800 withstands mechanical stress and electrical arcing. The current-limiting design reduces let-through energy during faults, protecting downstream equipment.

Flexible installation:

The breaker supports both front and rear cable connections, accommodating various panel layouts. The compact design allows for high-density installations, optimizing cabinet space utilization.

User-friendly features:

The ABB HC800 includes a clear status indication (ON/OFF/TRIPPED) and trip cause indication for quick troubleshooting. The rotary handle operation provides smooth and reliable manual control.

High reliability:

With a mechanical life of 20,000 operations and wide temperature range (-25°C to +70°C), the HC800 delivers dependable performance in diverse operating conditions.

Typical Application Scenarios

The ABB HC800 is extensively used in:

Industrial power distribution:

Main incoming protection for manufacturing facilities

Motor control center feeder protection

Machine tool power distribution

Commercial buildings:

Main LV switchboard protection

Generator backup system protection

Data center power distribution

Infrastructure projects:

Airport terminal power systems

Hospital emergency power circuits

Water treatment plant distribution

Renewable energy:

Solar farm combiner box protection

Wind turbine generator protection

Battery storage system integration

Related Model Recommendations

ABB HC630: Lower current version (630A)

ABB HC1000: Higher current version (1000A)

ABB EMAX2: Air circuit breaker for higher ratings

ABB SACE Tmax XT: Molded case breaker series

ABB PR123/P: Advanced trip unit option

ABB RCD: Residual current device add-on

ABB VD4: Vacuum circuit breaker for MV applications

ABB HC800

ABB HC800

Installation and Commissioning

Installation preparation:

Verify proper mounting rail or panel space is available. Ensure the installation environment meets specified temperature and humidity requirements. Prepare appropriate cable lugs for the conductor size.

Commissioning steps:

Mount the breaker securely

Connect power cables with proper torque

Set protection parameters according to design

Test mechanical operation

Verify trip unit functionality

Document all settings

Maintenance recommendations:

Perform regular operational tests

Check terminal connections annually

Clean exterior surfaces during maintenance

Verify protection settings remain correct

Exercise the mechanism periodically

Service and Guarantee Commitment

ABB provides:

5-year standard warranty

Global technical support network

24/7 emergency service

Replacement parts availability

Comprehensive documentation

The ABB HC800 is backed by ABB’s commitment to electrical safety and reliability, with long-term product support and continuous technical innovation in circuit protection technology.