ABB REF615 HBFFAEAGNDA1ABA11G | Relion 615 Series Feeder Relay | New / Surplus

  • Model:
  • Order Code: HBFFAEAGNDA1ABA11G
  • Brand: ABB / Hitachi Energy Relion 615 series
  • Core Function: Feeder protection and control IED for medium-voltage switchgear and distribution networks.
  • Product Type: MV Feeder Protection and Control Relay
  • Key Specs: Directional/non-directional overcurrent protection | Earth-fault protection | Voltage and frequency protection | IEC 61850 with GOOSE | Modbus / DNP3 / IEC 60870-5-103 | PCM600 engineering | Draw-out design
  • Condition: New Original / New Surplus
In Stock
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide. Brand:
The listed price is not final; the actual selling price is negotiable based on current market conditions.

Description

Product Core Brief

  • Model:
  • Order Code: HBFFAEAGNDA1ABA11G
  • Brand: ABB / Hitachi Energy Relion 615 series
  • Core Function: Feeder protection and control IED for medium-voltage switchgear and distribution networks.
  • Product Type: MV Feeder Protection and Control Relay
  • Key Specs: Directional/non-directional overcurrent protection | Earth-fault protection | Voltage and frequency protection | IEC 61850 with GOOSE | Modbus / DNP3 / IEC 60870-5-103 | PCM600 engineering | Draw-out design
  • Condition: New Original / New Surplus

Product Introduction

The ABB REF615 HBFFAEAGNDA1ABA11G is a feeder protection and control intelligent electronic device from the Relion 615 series. It is designed for medium-voltage distribution and industrial power systems, providing integrated protection, control, measurement, monitoring and communication for feeders, cables, transformers and capacitor banks.

REF615 supports directional and non-directional overcurrent protection, earth-fault protection, voltage and frequency protection, thermal overload protection, breaker failure protection and auto-reclose. It also provides synchrocheck, fault location, event recording and disturbance recording. The device is built with a compact draw-out design, making it suitable for replacement and spare-parts stocking in existing MV switchgear installations.

The order code HBFFAEAGNDA1ABA11G defines the hardware version, standard configuration, CT/VT inputs, binary I/O count, communication options and firmware features. Because REF615 variants differ by application package and I/O configuration, the full type code must be verified against the installed nameplate before procurement.

 

Key Technical Specifications

Parameter Value
Product Name REF615 Feeder Protection and Control IED
Order Code
Brand ABB / Hitachi Energy Relion 615 series
Primary Function Feeder protection, control, measurement and monitoring
Typical Applications MV feeders, cable circuits, transformer feeders, capacitor banks, industrial and utility distribution systems
Communication IEC 61850 with GOOSE, Modbus, DNP3, IEC 60870-5-103; PRP/HSR supported by REF615 family
Engineering Tool ABB PCM600
Hardware Design Compact draw-out unit with local HMI
Condition Available New Original / New Surplus

Note: Public sources confirm REF615 as an ABB Relion 615 series feeder protection IED with IEC 61850, directional overcurrent and earth-fault protection, and PCM600 configuration. However, the exact standard configuration, auxiliary voltage, I/O count, communication ports and firmware for order code HBFFAEAGNDA1ABA11G are not fully confirmed in open sources. Always verify the installed nameplate, hardware version and engineering data before replacement.

 

Quality Control Process

Each REF615 unit is inspected for housing condition, front-panel HMI, terminal blocks, communication ports, draw-out mechanism and nameplate data. Where test conditions allow, auxiliary power, LED indicators, HMI display and communication interfaces are checked to confirm basic readiness. The unit is packed with anti-static and shock-resistant protection to prevent damage to terminals, connectors and display components during transit.

 

Replacement Pitfall Guide

❗ Confirm the full order code. HBFFAEAGNDA1ABA11G must match the original device. Other REF615 order codes may differ in standard configuration, I/O count, communication options and firmware.

❗ Verify the hardware version. REF615 has multiple hardware versions, and software or configuration files may not be fully compatible across versions.

❗ Check the standard configuration package. Confirm whether the original unit is configured for feeder, transformer, capacitor or distributed-generation applications, and whether directional protection, voltage/frequency protection or auto-reclose is enabled.

❗ Review communication and IEC 61850 configuration. IEC 61850 edition, GOOSE mapping, Modbus/DNP3/IEC 60870-5-103 settings and time synchronization must match the existing substation design.

❗ Back up configuration before removal. Export protection settings, signal matrix, I/O mapping, communication parameters, event records and fault recordings from PCM600 or the existing IED. Photograph terminal wiring, DIP switches and HMI status before replacement.

 

Compatibility Matrix & Benchmarks

Original Model Replacement / Related Model Compatibility Level Migration Notes
ABB ABB REF615, same order code Direct Confirm hardware version, configuration and firmware
ABB Other REF615 variants Needs Adaptation Verify standard configuration, I/O, communication and CT/VT inputs
ABB ABB REF615E / REF620 Needs Engineering Different platform generation; engineering and I/O mapping must be reviewed
ABB ABB REF542plus / REF545 Not Direct Different platform family; wiring, HMI and configuration differ

Benchmarks

  • Platform: ABB / Hitachi Energy Relion 615 series feeder protection IED.
  • Typical use: MV feeder, cable, transformer and capacitor protection with integrated control, measurement and IEC 61850 communication.
  • Key advantage: compact draw-out design, preconfigured standard packages, PCM600 engineering and strong substation automation integration.

If you can share a nameplate photo, existing PCM600 project file, communication configuration and I/O list, I can help confirm whether HBFFAEAGNDA1ABA11G is a direct drop-in for your feeder bay.