ABB REC670 1MRK002814-AC | Replacement Bay Control IED, Surplus Stock

  • Model: REC670
  • Brand: ABB / Hitachi Energy
  • Series: Relion 670 series — bay control IED
  • Core Function: Controls, monitors, and protects switchgear apparatus in single, double, and multi-breaker bay arrangements, with optional backup protection functions.
  • Product Type: Bay control IED / substation control and protection relay
  • Key Specs: Select-before-operate control | GOOSE-based interlocking | IEC 61850 Ed.2 support | Synchrocheck | Local HMI
  • Condition: New Original / New Surplus, depending on stock
In Stock
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide. Brand:
The listed price is not final; the actual selling price is negotiable based on current market conditions.

Description

Product Core Brief

  • Model: REC670
  • Brand: ABB / Hitachi Energy
  • Series: Relion 670 series — bay control IED
  • Core Function: Controls, monitors, and protects switchgear apparatus in single, double, and multi-breaker bay arrangements, with optional backup protection functions.
  • Product Type: Bay control IED / substation control and protection relay
  • Key Specs: Select-before-operate control | GOOSE-based interlocking | IEC 61850 Ed.2 support | Synchrocheck | Local HMI
  • Condition: New Original / New Surplus, depending on stock

Product Introduction

ABB REC670 1MRK002814-AC is a high-performance bay control IED from the Relion 670 series. It is designed for transmission, sub-transmission, and industrial substations where reliable apparatus control, interlocking, measurement, and optional backup protection are required.

The REC670 supports control of breakers, disconnectors, and earthing switches based on the select-before-operate principle. It provides advanced interlocking, including GOOSE-based bay and station-wide interlocking, and can display status, alarms, measurements, and single-line diagrams on its local HMI. Depending on configuration, it may also include synchrocheck, auto-reclose, breaker-failure backup, overcurrent, voltage, and frequency protection functions.

The order code 1MRK002814-AC identifies a specific REC670 hardware/configuration variant within the Relion 670 family. The exact I/O, communication options, and application functions should be confirmed against the device nameplate and order documentation.

 

Key Technical Specifications

Parameter Value
Brand ABB / Hitachi Energy
Model
Order Code 1MRK002814-AC
Product Type Bay control IED
Typical Application Transmission, sub-transmission, and industrial substations
Control Function Breaker, disconnector, and earthing switch control
Interlocking GOOSE-based bay/station interlocking
Communication IEC 61850 MMS/GOOSE; dual Ethernet with PRP/HSR commonly available
Auxiliary Power Typically 85–265 V AC or 85–300 V DC, depending on power module
System Compatibility Relion 670 series protection and control ecosystem
Condition New Original / New Surplus

Quality Control Process

  • Order code verification: Confirm REC670 and 1MRK002814-AC match the original nameplate exactly.
  • Visual inspection: Check front HMI, terminal blocks, Ethernet/serial ports, mounting hardware, and signs of overheating.
  • Firmware and configuration check: Verify application package, control logic, interlocking settings, and firmware version.
  • Control loop test: Confirm select-before-operate, position indication, trip/close outputs, and synchrocheck if applicable.
  • Communication test: Verify IEC 61850/SCADA integration, GOOSE signals, time synchronization, and redundant Ethernet if configured.
  • Packing: Anti-static protection, moisture barrier, rigid corner protection, and shock-absorbing outer carton.

 

Replacement Pitfall Guide

❗ Confirm the full order code. 1MRK002814-AC defines the hardware/configuration variant; other REC670 order codes may differ in I/O, firmware, communication options, or application package.

❗ Do not treat it as a generic PLC controller. REC670 is a substation bay control IED, not a general-purpose PLC or DCS controller.

❗ Verify the application package. REC670 can be configured for feeder, transformer, bus-tie, coupler, or multi-breaker bays; wrong logic or interlocking settings may cause unsafe operation.

❗ Check GOOSE and IEC 61850 configuration. Interlocking, status exchange, and remote control depend on correct SCL/ICD files, IP addressing, and network settings.

❗ Confirm firmware compatibility. Relion 670 series firmware versions affect feature sets and cybersecurity posture; replacement units should match site requirements.

❗ Avoid blind replacement. Bay control IEDs are safety-critical; replacement should follow OEM procedures and site commissioning requirements.

Keep these in mind and you’ll cut 90% of rework time.

Compatibility Matrix & Benchmarks

Original Model Replacement / Successor Model Compatibility Level Migration Notes
ABB REC670 1MRK002814-AC ABB REC670 1MRK002814-AC Direct Match full order code, firmware, and configuration.
ABB REC670 1MRK002814-AC ABB REC670 other order code Needs Verification Same family but different I/O, firmware, or application package.
ABB REC670 1MRK002814-AC ABB REC650 bay control IED Needs Verification Different series; confirm I/O, communication, and engineering tool compatibility.
ABB REC670 1MRK002814-AC Generic PLC/controller module Not Compatible REC670 is a substation bay control IED, not a general-purpose PLC.

Benchmarks:

  • Relion 670-series bay control IED for transmission and industrial substations.
  • Supports select-before-operate control, GOOSE-based interlocking, IEC 61850 communication, synchrocheck, and local HMI monitoring.