8751-CA-NS

High – capacity Accommodation

The GE 8751 – CA – NS can house two Safetynet controllers simultaneously. This dual – controller support enhances system redundancy and processing power. In industrial settings where continuous operation is crucial, if one controller malfunctions, the other can seamlessly take over, minimizing downtime. For example, in a large – scale manufacturing plant, this ensures that production processes remain uninterrupted.

Earth Leakage Fault Detection

The built – in earth leakage fault detection terminals are a major advantage. In industrial environments, electrical safety is of utmost importance. The 8751 – CA – NS can quickly sense any earth leakage, allowing for immediate corrective action. This not only protects personnel from electrical shocks but also safeguards expensive equipment from potential damage due to electrical faults.

User – friendly Operation

With two serial port connections, it offers easy connectivity to a variety of devices. This enables seamless data transfer and communication within the industrial network. The manual “change state” buttons simplify the process of debugging and making on – the – fly adjustments to the system. Operators can easily access these buttons to troubleshoot issues or modify the system’s state without complex procedures.
In Stock
Manufacturer:
Part number: 8751-CA-NS
Our extensive catalogue, including : 8751-CA-NS , is available now for dispatch to the worldwide. Brand:

Description

Product Overview

The GE 8751 – CA – NS is a controller carrier developed by General Electric, playing a pivotal role in industrial automation systems. Specifically designed for the Safetynet system, it offers a stable and efficient platform for seamless control operations. This carrier is engineered to accommodate up to two Safetynet controllers, enabling coordinated and enhanced control functionality within the industrial setup. With terminals for earth leakage fault detection, it significantly bolsters the safety aspect of the overall system. By promptly identifying potential earth leakage faults, it helps prevent electrical hazards and ensures continuous and secure operation. The GE 8751 – CA – NS also comes equipped with two serial port connections, facilitating smooth communication with other devices in the network. Additionally, the manual “change state” buttons provide users with convenient means for operation and debugging, making it easier to fine – tune the system as per requirements.

Technical Specifications

Parameter Name Parameter Value
Product Model 8751 – CA – NS
Manufacturer General Electric
Product Type Controller Carrier
Operating Voltage 220V
Output Frequency 50kHz
Dimensions 263×58×28 mm
Weight 4.3 kg
Connector Type 9 – pin, D – type (female) (x2)
Mounting Type Flat panel (4 fixings)
Accommodation Two Safetynet controllers, power supply monitor module
Earth Leakage Detection Yes
IC697MDL250

IC697MDL250

Main Features and Advantages

High – capacity Accommodation

The GE 8751 – CA – NS can house two Safetynet controllers simultaneously. This dual – controller support enhances system redundancy and processing power. In industrial settings where continuous operation is crucial, if one controller malfunctions, the other can seamlessly take over, minimizing downtime. For example, in a large – scale manufacturing plant, this ensures that production processes remain uninterrupted.

Earth Leakage Fault Detection

The built – in earth leakage fault detection terminals are a major advantage. In industrial environments, electrical safety is of utmost importance. The 8751 – CA – NS can quickly sense any earth leakage, allowing for immediate corrective action. This not only protects personnel from electrical shocks but also safeguards expensive equipment from potential damage due to electrical faults.

User – friendly Operation

With two serial port connections, it offers easy connectivity to a variety of devices. This enables seamless data transfer and communication within the industrial network. The manual “change state” buttons simplify the process of debugging and making on – the – fly adjustments to the system. Operators can easily access these buttons to troubleshoot issues or modify the system’s state without complex procedures.

Application Field

In the manufacturing industry, the GE 8751 – CA – NS finds extensive use. For instance, in automotive manufacturing plants, it can be used to control and monitor the production lines. The carrier’s ability to support multiple controllers allows for coordinated control of different manufacturing processes, such as robotic assembly, painting, and quality inspection. In power generation facilities, it plays a vital role in safeguarding electrical systems. By detecting earth leakage faults, it helps maintain the integrity of the power generation and distribution network. This is crucial for ensuring a stable power supply to consumers. Chemical plants also benefit from the 8751 – CA – NS. In these plants, where hazardous materials are often processed, electrical safety is critical. The carrier’s safety features, along with its control capabilities, help manage the complex chemical processes while ensuring the safety of the plant and its workers.

IS210MACCH1AKH

IS210MACCH1AKH

Related Products

  • 8851 – LC – MT: These are Safetynet controllers that can be mounted on the GE 8751 – CA – NS. They work in tandem with the carrier to execute control functions, with the carrier providing the necessary physical and electrical interface for the controllers.
  • 8410 – NS – PS: A power supply monitor module that can be installed on the 8751 – CA – NS. It monitors the health of power supplies like 8913 – PS – AC and 8914 – PS – AC, ensuring stable power delivery to the overall system.
  • 8750 – CA – NS: Similar to the 8751 – CA – NS, it is also a controller carrier. However, it lacks the earth leakage fault detection feature, making it suitable for applications where this specific safety feature is not a requirement.
  • 8811 – IO – DC: A discrete I/O module that can be used in combination with the GE 8751 – CA – NS in scenarios where earth leakage fault detection needs to be integrated with input/output operations.
  • 8913 – PS – AC: An AC power supply that can be monitored by the 8410 – NS – PS module when installed on the 8751 – CA – NS, providing the necessary electrical power for the overall system to function.

Installation and Maintenance

Pre – installation preparation: Before installing the GE 8751 – CA – NS, ensure that the installation area is clean, dry, and free from excessive vibrations. Check the integrity of the module for any visible signs of damage during transit. Familiarize yourself with the layout of the industrial system where it will be installed, especially the location of other components it will interface with. Make sure the power supply to the area is turned off to avoid electrical accidents during installation. Prepare the necessary tools, such as screwdrivers for the flat panel mounting.

 

Maintenance recommendations: Regularly inspect the 8751 – CA – NS for any signs of overheating, unusual noises, or visual damage. Clean the module periodically to remove dust and debris, as these can affect its performance over time. Check the earth leakage fault detection functionality regularly to ensure it is working correctly. If any issues are detected, refer to the manufacturer’s documentation for troubleshooting steps. Keep the serial port connections clean and free from corrosion to maintain optimal communication.

Product Guarantee

GE stands firmly behind the quality of the GE 8751 – CA – NS. The product undergoes rigorous quality – control measures during manufacturing to meet high – industry standards. GE offers a one – year warranty for the 8751 – CA – NS. In case of any manufacturing defects within this period, the company provides free repair or replacement services. Their global network of technical support teams is available to assist customers with any queries related to installation, operation, or maintenance. This reflects GE’s confidence in the product’s reliability and its commitment to customer satisfaction, ensuring that industrial users can rely on the 8751 – CA – NS for their automation needs.