Product Core Brief
- Model: SPAJ110C
- Brand: ABB
- Series: ABB SPACOM SPAJ 110 C earth-fault relay family
- Core Function: Selective earth-fault protection relay for solidly earthed or low-resistance earthed power systems; provides primary or backup earth-fault protection for feeders, transformers, generators, and motors.
- Product Type: Earth-fault protection relay
- Key Specs: Low-set I₀> (IDMT or definite-time) + high-set I₀>> (definite-time) | Serial interface | Self-supervision | Legacy ABB component
- Condition: New Original / New Surplus (verify by full order code and suffix)
Key Technical Specifications
- Part Number:
- Product Type: Earth-fault protection relay (SPACOM family)
- System Role: Provides selective earth-fault protection as primary or backup protection in solidly earthed or low-resistance earthed power systems
- Protection Stages: Two-stage neutral overcurrent — low-set I₀> and high-set I₀>>
- Time Characteristics: Low-set I₀>: definite-time or inverse-time (IDMT); High-set I₀>>: definite-time only
- Auxiliary Supply Voltage: Typically 80–265 V AC/DC (SPTU 240 S1) or 18–80 V DC (SPTU 48 S1); verify against the actual relay nameplate
- Frequency: 50/60 Hz (per order)
- CT Input: 1 A or 5 A rated current (verify against nameplate)
- Outputs: Typically 2 heavy-duty trip relays + 4 signal relays (configurable); verify against the actual unit
- Communication: Serial interface for connection to fiber-optic object bus and substation/network control systems
- Self-Supervision: Continuous hardware and software auto-diagnostics
- Mounting: Flush or semi-flush panel mounting; IP54 enclosure degree of protection for panel-mounted relay
- Lifecycle Status: Not active product since 2009; spare parts supply only
Product Introduction (No Fluff)
The ABB SPAJ110C is an earth-fault protection relay from the SPACOM family, designed for selective earth-fault protection in solidly earthed or low-resistance earthed power systems. It provides two protection stages — a low-set I₀> stage with definite-time or IDMT characteristic and a high-set I₀>> stage with definite-time characteristic — making it suitable as primary or backup earth-fault protection for feeders, transformers, generators, and motors.
Its practical value is maintaining legacy ABB distribution automation and substation installations where a failed earth-fault relay can compromise ground-fault selectivity and coordination. The relay can be configured to cooperate with a residual voltage relay for blocking/deblocking operation. For maintenance replacements, the full order code (e.g., SPAJ110C RS 421 010/210 -AA, -CA, -DA, -FA) and auxiliary voltage suffix should be matched against the existing relay label, since power supply range, test adapter configuration, and communication options may differ across variants.
QA & Testing SOP (Dynamic & Transparent)
For legacy earth-fault relays, we verify mechanical integrity and basic readiness before shipping.
- Part number verification — Confirm SPAJ110C and the full order code/suffix on the label; check auxiliary voltage marking.
- Visual inspection — Inspect the front panel, display, connectors, terminal blocks, and mounting clips for corrosion, burn marks, or mechanical damage.
- Connector and terminal check — Verify CT input terminals, trip/signal output terminals, serial communication port, and auxiliary supply terminals for oxidation, loose contacts, or contamination.
- Insulation and short-circuit check — Confirm no short circuits between CT inputs, auxiliary supply, and output circuits before energizing.
- Power-up verification — Where test fixtures are available, apply rated auxiliary voltage and verify display, LED indicators, relay self-test, and output operation; pack with terminal protection.
Installation Pitfalls & Guide (Engineer to Engineer)
❗ Match the full order code and suffix. SPAJ110C variants differ in auxiliary voltage (e.g., 80–265 V AC/DC vs. 18–80 V DC), test adapter configuration, and communication options. Substituting without verification can cause wiring or compatibility mismatches.
❗ Verify CT polarity and zero-sequence connection. Incorrect CT polarity or residual current connection can cause false trips or failure to detect earth faults.
❗ Confirm auxiliary supply voltage. The relay supports multiple auxiliary voltage ranges depending on the power supply module installed. Verify against the nameplate before energizing.
❗ Back up relay settings. Before replacement, record all protection settings, including I₀> and I₀>> pickup values, time delays, IDMT curve selection, and blocking/deblocking configuration.
❗ Test with secondary injection. After installation, verify both earth-fault stages, trip/signal outputs, serial communication, and self-supervision functions using secondary injection testing before returning the feeder or transformer to service.
Replacement steps:
- Record all relay settings, CT ratios, wiring connections, and communication configuration.
- Remove auxiliary supply and verify zero voltage before disconnecting CT and trip circuits.
- Install the replacement SPAJ110C with the same full order code and restore all settings.
- Apply auxiliary supply, verify self-test, and perform secondary injection testing on both earth-fault stages.
Technical FAQ
What does the SPAJ110C do? It is an earth-fault protection relay providing selective ground-fault protection with two stages (I₀> and I₀>>) for feeders, transformers, generators, and motors in solidly or low-resistance earthed systems.
What is the difference between SPAJ110C variants? Variants differ in auxiliary supply voltage range (e.g., 80–265 V AC/DC vs. 18–80 V DC), whether a test adapter RTXP 18 is included, and communication/interface options. The full order code on the nameplate should always be confirmed before ordering.
Can it coordinate with a residual voltage relay? Yes. The relay can be configured to cooperate with a residual voltage relay for blocking/deblocking earth-fault operation.
Is it still available? It has been a non-active product since 2009. New surplus and verified replacements can be sourced, but long-term projects should evaluate migration to a supported ABB protection relay platform.